Custom cover image
Custom cover image

Development of 15 Micron Cutoff Wavelength HgCdTe Detector Arrays for Astronomy / by Mario Cabrera

By: Resource type: Ressourcentyp: Buch (Online)Book (Online)Language: English Series: Springer Theses, Recognizing Outstanding Ph.D. ResearchPublisher: Cham : Springer International Publishing, 2020Publisher: Cham : Imprint: Springer, 2020Edition: 1st ed. 2020Description: 1 Online-Ressource(XVII, 121 p. 71 illus., 44 illus. in color.)ISBN:
  • 9783030542412
Subject(s): Additional physical formats: 9783030542405 | 9783030542429 | 9783030542436 | Erscheint auch als: 9783030542405 Druck-Ausgabe | Erscheint auch als: 9783030542429 Druck-Ausgabe | Erscheint auch als: 9783030542436 Druck-AusgabeDOI: DOI: 10.1007/978-3-030-54241-2Online resources: Summary: Chapter1: Introduction -- Chapter2: Test and Data Acquisition Setup -- Chapter3: Dark Current Theory -- Chapter4: Array Characterization -- Chapter5: Phase I Results: 13 m Cuto Wavelength Devices -- Chapter6: Phase II Results: 15 m Cuto Wavelength Devices -- Chapter7: Conclusions and Future Work.Summary: This thesis describes advances in the understanding of HgCdTe detectors. While long wave (15 μm) infrared detectors HgCdTe detectors have been developed for military use under high background irradiance, these arrays had not previously been developed for astronomical use where the background irradiance is a billion times smaller. The main pitfall in developing such arrays for astronomy is the pixel dark current which plagues long wave HgCdTe. The author details work on the success of shorter wavelength development at Teledyne Imaging Sensors, carefully modeling the dark current–reverse bias voltage curves of their 10 μm devices at a temperature of 30K, as well as the dark current–temperature curves at several reverse biases, including 250 mV. By projecting first to 13 and then 15 μm HgCdTe growth, values of fundamental properties of the material that would minimize tunneling dark currents were determined through careful modeling of the dark current-reverse bias voltage curves, as well as the dark current-temperature curves. This analysis was borne out in the 13 μm parts produced by Teledyne, and then further honed to produce the necessary parameters for the 15 μm growth. The resulting 13 μm arrays are being considered by a number of ground-based astronomy research groups.PPN: PPN: 1734625368Package identifier: Produktsigel: ZDB-2-PHA | ZDB-2-SEB | ZDB-2-SXP
No physical items for this record

Powered by Koha